These are the equations which is used to calculate various things during chromatography including column volume, media requirements for column, resolution etc
Total or Empty column volume
Ve = π * r2 * L or 1/4 π * d2 * L
Ve = empty column volume
r = column radius
L = length of the column (or packed bed)
D = column diameter
If r (or d) and L are expressed in mm, Ve will be in µL. If in cm, then Ve in mL.
Volumetric Flow Rate (VFR) Calculation from Linear Flow Rate (LFR)
This can be useful because the chromatographic media has certain flow rate specification at which it can be operated, for example a chromatographic media specification says use 150 cm/hr flow rate so while setting up the flow rate in peristaltic pump or in other automated system like AKTA volumetric flow rate need to be calculated, using the equation below it can be calculated.
VFR (ml/min) = LFR(cm/hr) / 60 * πr2
we need 150cm/hr and the column used has a diameter of 0.5cm or 0.25cm as radius so,
VFR = 150/60 * 3.14 * (0.25)2 ;
Volumetric flow rate will be ~ 0.5 ml/min
Linear Flow Rate (LFR) Calculation from Volumetric Flow Rate (VFR)
LFR(cm/hr) = VFR(ml/min) * 60 / πr2
Similarly we need 1ml/min and the column used has a diameter of 0.5cm or 0.25cm as radius so,
LFR(cm/hr) = 1 * 60 / ( 3.14 * (0.25)2 )
Linear flow rate will be ~ 300 cm/hr
Bed Volume
Bed volume (L) = Bed height (cm) * Column cross-sectional area (cm2) / 1000
cross-sectional area = π * r2
Packed Bed Volume
Packed bed volume (L) = Column bed height (cm) * cross-sectional area (cm2) * x10-3
cross-sectional area = π * r2
Settled chromatography medium volume
Settled chromatography medium volume (L) = Packed bed volume (L) * compression factor
compression factor can be obtained from the chromatographic media specification sheet.
Slurry volume
Slurry volume (L) = Settled chromatography medium volume (L) / (slurry concentration (%) * x 10-2)
The chromatography medium volume for HIC, IEX, Affinity, Reverse Phase
The chromatography medium volume is calculated from the formula:
The chromatography medium volume (L) =
(Quantity to be bound (g) * (1+ safety margin (%) / 100)) / (Dynamic binding capacity (g/L)
The chromatography medium volume for Gel Filtration Chromatography
The chromatography medium volume (L) =
Sample volume to be processed (L) / (Sample volume in percent of total column volume (%) / 100)
Resolution (Rs)
Chromatographic peak resolution can be calculated using the following equation
Rs = (tR1 – tR2) / 0.5(W1 + W2)
Rs – Resolution
tR1 – Retention time of the first peak
tR2 – Retention time of the second peak
w1 – Width of first peak
w2 – width of second peak
Sources & References
GE Life Sciences – Chromatography medium volume calculators
Tosoh Bioscience LLC: The Chemistry of Innovation – Technical Support – Basic Chromatographic Calculations
Got something to say about this post? Leave a comment…your comments are valuable for improving the posts.